Dimensions Height x Width x Depth (basic version without options)
|
1110 x 800 x 510 mm<br />43.31 x 31.50 x 20.08 in |
Height with wheel option |
no difference |
Height with rising socket option 100 mm |
+100 mm (+3.94 in) |
Height with Application Box option *3 |
+540 mm (+21.26 in) |
Height with air conditioner option |
+340 mm (+13.38 in) |
Height with autotransformer option |
+200 mm (+7.87 in) |
Weight Control Unit (standard version) The weight specified may change depending on the configuration, in particular when it deals with the version featuring Application Box and autotransformer. Always refer to the plate posted on the Control Unit
|
125 kg / 275 lb without packaging
|
Air conditioner (optional) |
+31 kg / 68 lb |
Autotransformer (optional) |
+40 kg / 88 lb |
Power supply data Power supply voltage (according to EN 60204-1 § 4.3.3 standard, voltage interruption not exceeding 20 ms)
|
from 400 Vac -10% to 480 Vac +10%<br />(optional from a 500 Vac -10% to 575 Vac +10%)*1
|
Frequency (according to EN 60204-1 § 4.3.3 standard) |
50 a 60 Hz (±2 Hz) |
Main switch interruption power |
Standard Models 6 kA a 500 Vac North America Models 8 kA a 500 Vac
Note: On Control Unit North America model the sectioning device is a pure isolating switch
|
Power installed |
from 4 to 12 kVA (see Tab. 3.2) |
Auxiliary circuits power |
24 Vdc |
Environment conditions Cabinet protection (rear compartment excluded) (according to EN 60529 standard)
|
IP 54 / NEMA 12
|
Rear compartment protection (according to EN 60529 standard) |
IP 2x |
Environment temperature without cooling systems (Test conditions according to EN 60068-2-14 standard) |
from +5 °C to +45 °C *2 <br />from +41 °F a 113 °F |
Environment temperature with cooling systems (Test conditions according to EN 60068-2-14 standard) |
from +5 °C to +55 °C *2from +41 °F a 131 °F |
Environment storage temperature (according to EN 60204-1 § 4.5 standard) |
from -25 °C a +55 °C <br /> from -13 °F a 131 °F <br />+70 °C / 158 °F for periods shorter one hour |
Maximum temperature gradient |
1,5 °C/minute <br />2,7 °F/minute |
Relative humidity
(according to EN 60204-1 § 4.4.4, test conditions HD 323.2.3. S2) |
from 5% to 95% without condensation
|
Altitude of the installation site (according to EN 60204-1 § 4.4.5 standard) |
from 0 a 1.000 m / 0 to 3280 ft above mean sea level |
Axis controlling capability Total for the system
|
up to 16 axes |
Control Unit without expansion cabinets |
up to 11 axes |
Cooling Standard cabin model |
Natural convention |
Cabin with cooling options |
Air conditioner |
Drive command |
Forced air recirculation |
Vibrations and crashes Sine vibration (according to EN 60068-2-64 standard)
|
Frequency 10 - 250 Hz <br /> 0.6 g rms axis Z acceleration 0.2 g rms axes X-Y acceleration |